Flexural Strength & Surface Tension Test — 10mm MGO Board

Views :
Update time : 2026-06-15

Flexural Strength & Surface Tension — 10mm MGO Board



ASTM C1185 / D1037 test on a second batch of 10mm pure sulfate MGO board. Equilibrium-conditioned flexural strength averages 22.8 MPa; wet-conditioned averages 17.1 MPa; maximum tensile stress parallel to surface up to 5.72 MPa. Consistent mechanical quality across production batches.

10mm Flexural Strength andTension Parallel to Surface-1.pdf


Related News
Read More >>
Flexural Strength Test — 18mm Flexural Strength Test — 18mm
06 .15.2026
Flexural Strength Test — 18mm MGO Subfloor BoardASTM C1185 flexural strength test on 18mm pure sulfa...
Flexural Strength & Surfac Flexural Strength & Surfac
06 .15.2026
Flexural Strength & Surface Tension — 10mm MGO BoardASTM C1185 / D1037 test on a second batch of...
VOC Emission Test —Pure Sulfat VOC Emission Test —Pure Sulfat
06 .15.2026
VOC Emission Test —Pure Sulfate MGO Board (ISO 16000) Emission chamber test by Intertek per ISO 1600...
VOC test--pure sulfate mgo boa VOC test--pure sulfate mgo boa
05 .26.2026
Just got the Intertek test report for our magnesium oxide board.38 harmful substances fully tested —...