Flexural Strength Test — 18mm MGO Subfloor Board

Views :
Update time : 2026-06-15

Flexural Strength Test — 18mm MGO Subfloor Board


ASTM C1185 flexural strength test on 18mm pure sulfate MGO subfloor board. Equilibrium-conditioned flexural strength averages 25.2 MPa; wet-conditioned averages 21.5 MPa. Confirmed as a structural subfloor for residential and light commercial flooring systems.